Answer

Hello Laura, You would want to check to see if the spark module has failed. To check this you would attach meter lead to L wire terminal on spark module and attach other meter lead to N or white. Reconnect power to unit and turn all knobs on light position. If there is no voltage (120vac) at test meter indicates the electrical circuit is interrupted before spark module. If there is voltage then check ignitors by attaching one meter lead to a good ground and the other meter lead to an ignitor terminal. A continuity reading indicates that there is a short to ground and ignitor needs replaced. If no continuity then touch other grounded meter lead to the opposite end of ignitor lead which is attached to top burner mounting bracket. No continuity indicates open circuit in ignitor WP3185804 lead wire and need to replace ignitor. If ignitors are ok then replace spark moduleY705823.

Read More...

Answered by AppliancePartsPros.com   |   Tuesday, November 20, 2012

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store