Questions & Answers

For Ge Freezer Electronic Temperature Control Board (Part Number: OEM15530562)

1 Answer

Papamike, if the display acts as though a button is being pressed to set the temperature colder, the failure would be in the control WR55X11084.

Read More...

1 Answer

Anthony, When you look at the control board there will be a CN4 connector and is a 9 pin connector and you will test pin 1 to pin 7 for resistance. The resistance of the thermistor at 0 degrees should be approximately 17K ohms.

Read More...

1 Answer

Raven, If the refrigerator is cooling down to the proper operating temperature then there would be nothing that needs to be done. If the unit is sitting in a garage it may be that the garage is too hot. The ambient room temperature should be between 55 and 95 degrees and you will want to make sure that there is nothing surrounding it which would cause heat to be trapped in. The high temp alarm will not come on unless there is a high temp above 15 to 20 degrees.

Read More...

1 Answer

Barry, Your control in the door senses the temperature of the unit and tells the compressor when to run based off a reading of the thermistor. The manufacturer doesn't provide the thermistor readings to test but will usually run just shut off more frequently. I believe you will need the control WR55X11084

Read More...

1 Answer

Hello Les. Based on the information you provided, you have sealed system failure and will need an HVAC tech to come out and repair the unit. Thanks.

Read More...

1 Answer

Lisa, That code is not coming up as valid and the most likely cause for this issue will be the either the control board is bad or the compressor is not running due to a faulty overload/relay.

Read More...
Kevin for Model Number GE FUF 17SVCRWW

I have this GE FUF 17SVCRWW upright freezer. After a few years the digital display on the control panel dose not light up. Other than that the freezer seems to be working properly. Keeping temp at 14 degrees F. I did remove the panel and put it back in - no change - still no display and the freezer is working well. I am just wondering should I be concerned that the freezer could stop working? It has performed well like this for several years. Thank you!

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store